ZipTap Report

Houston, TX · tap water

What’s in Houston tap water

Houston Public Works (City of Houston Main System), from its 2025 Water Quality Report (Jan–Dec 2025) and EPA’s federal record.

PWSID TX1010013 2,970,543 people served (SDWIS) Surface water Checked Nov 19, 2026
2,970,543people served, per EPA SDWIS
5 ppblead, 90th percentile in EPA SDWIS (period ending Jun 30, 2024)
1health-based violation record in SDWIS (all years)
1SDWIS violation records of any type since 2021

Houston’s report covers several separate systems. The figures below are from the “Main System | TX1010013” tables (pages 7–8). Houston disinfects with chloramines. Some Houston-area addresses get water from other systems, such as municipal utility districts, so check the name on your bill. Source: 2025 Water Quality Report (Jan–Dec 2025), checked Nov 19, 2026.

Houston Public Works (City of Houston Main System): highlights from the 2025 Water Quality Report (Jan–Dec 2025). Values as printed by the utility.
SubstanceReported valueRange / detailLimit or goal shown in the reportFilter certification that covers it
Lead (home taps, 90th percentile)5.1 ppbNo samples above 15 ppbAction level 15 ppb; goal 0NSF/ANSI 53NSF/ANSI 58
Claim: “Lead Reduction”
Copper (home taps, 90th percentile)0.22 ppmNo samples above 1.3 ppmAction level 1.3 ppmNSF/ANSI 53NSF/ANSI 58
Claim: “Copper Reduction”
Total trihalomethanes (TTHM)43.6 ppb (highest LRAA)ND – 47.7 ppbMCL 80 ppb (as LRAA)NSF/ANSI 53NSF/ANSI 58
Claim: “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)40.8 ppb (highest LRAA)ND – 55.9 ppbMCL 60 ppb (as LRAA)No HAA5 claim category in NSF’s listing search
Arsenic (at plants)1.7 ppb (average)ND – 6.7 ppbMCL 10 ppbNSF/ANSI 53NSF/ANSI 58
Claim: “Arsenic (Pentavalent) Reduction”
Nitrate (distribution)0.35 ppm (average)ND – 1.40 ppmMCL 10 ppmNSF/ANSI 58
Claim: “Nitrate/Nitrite Reduction”
Fluoride (at plants)0.11 ppm (average)ND – 0.71 ppmMCL 4 ppmNSF/ANSI 58
Claim: “Fluoride Reduction”
Chloramines (disinfectant)2.8 ppm (average)0.04 – 4.8 ppmMRDL 4.0 ppmNSF/ANSI 42
Claim: “Chloramine Reduction”
Total hardness as CaCO3135.5 ppm (average)43.5 – 229 ppmNo limitNSF/ANSI 44
Claim: “Hardness Reduction”

The report shows chloramine single results up to 4.8 ppm; the 4.0 ppm MRDL is a running-average limit, and the report’s violation column is not shown for this row in our extract, so we make no compliance statement about it. Total coliforms: highest monthly positive 2.7% against a 5% limit. Filter column: claim names and standards from NSF’s certified-product listing search, checked Nov 19, 2026. A standard number alone is not enough: the specific model must be listed for that claim.

What these numbers can and cannot tell you

These are the utility’s system-wide figures. Lead usually comes from a building’s own pipes and fixtures, so your tap can differ from the 90th percentile. EPA’s lead page explains this: EPA, Basic Information about Lead in Drinking Water, checked Nov 19, 2026. For health questions, talk to your doctor.

Lead at home taps: EPA’s federal record

90th-percentile lead (ppb) in EPA SDWIS for TX1010013, last 3 sampling periods, against the 15 ppb action level. Source: EPA Envirofacts LCR_SAMPLE_RESULT and LCR_SAMPLE, checked Nov 19, 2026.Action level 15 ppb020223202352024
90th-percentile lead (ppb) in EPA SDWIS for TX1010013, last 3 sampling periods, against the 15 ppb action level. Source: EPA Envirofacts LCR_SAMPLE_RESULT and LCR_SAMPLE, checked Nov 19, 2026.
Lead 90th percentile by sampling period, EPA SDWIS (TX1010013)
Sampling period90th-percentile lead
Jan 1, 2017 – Dec 31, 20194.01 ppb
Jul 1, 2021 – Dec 31, 20213.4 ppb
Jan 1, 2022 – Jun 30, 20220 ppb
Jul 1, 2023 – Dec 31, 20233 ppb
Jan 1, 2024 – Jun 30, 20245 ppb

Violations in EPA’s record

SDWIS lists 3 violation records for this system in total. Most are monitoring or reporting records. The health-based ones are below, with EPA’s own labels and status.

Health-based violation records, EPA SDWIS (TX1010013)
Compliance periodRuleViolation typeStatus in SDWIS
May 1, 2025 – May 31, 2025Interim Enhanced Surface Water Treatment RuleSingle Turbidity Exceed (Enhanced SWTR)Returned to Compliance (Jul 1, 2025)

Sources: EPA Envirofacts VIOLATION table, checked Nov 19, 2026; code labels from EPA’s SDWA reference code file (ECHO SDWA data download, checked Nov 19, 2026). The full federal report: EPA ECHO detailed facility report.

Which filter to look for, based on this report

Match the items you care about to a model that is listed for that claim. Our filter guide explains each type. Two items here are worth knowing:

ZIP codes we match to Houston

57 ZIP codes lie at least 90% inside Houston by land area (Census 2020): 77002, 77003, 77004, 77006, 77007, 77008, 77009, 77010, 77011, 77012, 77013, 77017, 77018, 77019, 77020, 77021, 77022, 77023, 77025, 77026, 77027, 77028, 77030, 77033, 77034, 77035, 77036, 77042, 77043, 77045, 77046, 77048, 77051, 77054, 77056, 77057, 77061, 77062, 77063, 77072, 77074, 77075, 77076, 77077, 77079, 77080, 77081, 77085, 77087, 77091, 77092, 77096, 77098, 77099, 77204, 77339, 77345.

Reserved

Space reserved for a future, clearly labeled filter retailer link. No affiliate links are live on this site.

Sources

  1. 2025 Water Quality Report (Jan–Dec 2025) (Houston Public Works (City of Houston Main System)) (houstonpublicworks.org, checked Nov 19, 2026)
  2. Report page (houstonpublicworks.org, checked Nov 19, 2026)
  3. EPA Envirofacts WATER_SYSTEM TX1010013 (data.epa.gov, checked Nov 19, 2026)
  4. EPA Envirofacts VIOLATION TX1010013 (data.epa.gov, checked Nov 19, 2026)
  5. EPA Envirofacts LCR_SAMPLE_RESULT TX1010013 (data.epa.gov, checked Nov 19, 2026)
  6. NSF certified drinking water treatment units listing search (info.nsf.org, checked Nov 19, 2026)
  7. U.S. Census 2020 ZCTA to place relationship file (www2.census.gov, checked Nov 19, 2026)