New York City, NY · tap water
What’s in New York City tap water
NYC Department of Environmental Protection (DEP), from its 2025 Drinking Water Supply and Quality Report and EPA’s federal record.
ZIP lies mostly inside New York City (Census 2020). Check the utility name on your water bill to confirm this is your system.
NYC DEP says its 2025 report shows the city’s water “met all drinking water standards in 2025.” The supply is surface water from upstate reservoirs (Catskill/Delaware and Croton). The report says DEP adds chlorine, fluoride, food-grade phosphoric acid and sodium hydroxide. Source: 2025 Drinking Water Supply and Quality Report, checked Nov 19, 2026.
| Substance | Reported value | Range / detail | Limit or goal shown in the report | Filter certification that covers it |
|---|---|---|---|---|
| Lead (home taps, 90th percentile) | 10 µg/L (ppb) | ND – 155 µg/L; 16 of 326 homes above 15 | Action level 15 µg/L; goal 0 | NSF/ANSI 53NSF/ANSI 58 Claim: “Lead Reduction” |
| Copper (home taps, 90th percentile) | 0.194 mg/L | 0.007 – 1.350 mg/L; 1 of 326 homes above 1.3 | Action level 1.3 mg/L | NSF/ANSI 53NSF/ANSI 58 Claim: “Copper Reduction” |
| Total trihalomethanes (TTHM) | 52 µg/L (highest LRAA) | 4 – 81 µg/L | MCL 80 µg/L (as LRAA) | NSF/ANSI 53NSF/ANSI 58 Claim: “Trihalomethanes (TTHM) Reduction” |
| Haloacetic acids (HAA5) | 47 µg/L (highest LRAA) | 7 – 64 µg/L | MCL 60 µg/L (as LRAA) | No HAA5 claim category in NSF’s listing search |
| PFOA | ND (average) | ND – 2.7 ng/L (one detection) | NYSDOH MCL 10 ng/L | NSF/ANSI 53 Claim: “PFOA Reduction / PFOS Reduction / Total PFAS Reduction” |
| Nitrate (as nitrogen) | 0.14 mg/L (average) | 0.07 – 0.37 mg/L | MCL 10 mg/L | NSF/ANSI 58 Claim: “Nitrate/Nitrite Reduction” |
| Fluoride | 0.7 mg/L (average) | ND – 0.8 mg/L | NYSDOH MCL 2.2 mg/L | NSF/ANSI 58 Claim: “Fluoride Reduction” |
| Free chlorine residual | 0.6 mg/L (average) | ND – 1.4 mg/L | MRDL 4 mg/L | NSF/ANSI 42NSF/ANSI 53 Claim: “Chlorine Reduction” |
| Hardness | 32 mg/L as CaCO3 (about 2 grains/gal) | 18 – 100 mg/L | No limit (report calls up to 3 grains/gal soft) | NSF/ANSI 44 Claim: “Hardness Reduction” |
| Sodium | 16 mg/L (average) | 9 – 49 mg/L | No MCL; report notes a 20 mg/L level for very low-sodium diets | NSF/ANSI 58 Claim: “TDS Reduction” |
TTHM and HAA5 “Average” values are the highest locational running annual average (LRAA), per the report’s footnote 16. The PFOA detection was one sample on Jan 8, 2025 (footnote 19). Lead and copper come from the report’s “Lead and Copper Rule Residential Tap Sampling” table. Filter column: claim names and standards from NSF’s certified-product listing search, checked Nov 19, 2026. A standard number alone is not enough: the specific model must be listed for that claim.
What these numbers can and cannot tell you
These are the utility’s system-wide figures. Lead usually comes from a building’s own pipes and fixtures, so your tap can differ from the 90th percentile. EPA’s lead page explains this: EPA, Basic Information about Lead in Drinking Water, checked Nov 19, 2026. For health questions, talk to your doctor.
Lead at home taps: EPA’s federal record
| Sampling period | 90th-percentile lead |
|---|---|
| Jan 1, 2021 – Dec 31, 2021 | 12 ppb |
| Jan 1, 2022 – Dec 31, 2022 | 11 ppb |
| Jan 1, 2022 – Dec 31, 2022 | 11 ppb |
| Jan 1, 2023 – Dec 31, 2023 | 11 ppb |
| Jan 1, 2024 – Dec 31, 2024 | 10 ppb |
Violations in EPA’s record
SDWIS lists 10 violation records for this system in total. Most are monitoring or reporting records. The health-based ones are below, with EPA’s own labels and status.
| Compliance period | Rule | Violation type | Status in SDWIS |
|---|---|---|---|
| Feb 1, 2017 | Long Term 2 Enhanced Surface Water Treatment Rule | Treatment Technique Uncovered Reservoir | Open |
Sources: EPA Envirofacts VIOLATION table, checked Nov 19, 2026; code labels from EPA’s SDWA reference code file (ECHO SDWA data download, checked Nov 19, 2026). The full federal report: EPA ECHO detailed facility report.
Which filter to look for, based on this report
Match the items you care about to a model that is listed for that claim. Our filter guide explains each type. Two items here are worth knowing:
- For lead, NSF’s listings show “Lead Reduction” claims under NSF/ANSI 53 and 58.
- For PFAS, NSF’s listings show PFOA, PFOS and Total PFAS reduction claims under NSF/ANSI 53, and NSF says 53 and 58 devices are an effective way to limit exposure.
- For nitrate, fluoride, arsenic or sodium/TDS, the listings show reduction claims under NSF/ANSI 58 (reverse osmosis).
ZIP codes we match to New York City
211 ZIP codes lie at least 90% inside New York City by land area (Census 2020): 10001, 10002, 10003, 10004, 10005, 10006, 10007, 10009, 10010, 10011, 10012, 10013, 10014, 10016, 10017, 10018, 10019, 10020, 10021, 10022, 10023, 10024, 10025, 10026, 10027, 10028, 10029, 10030, 10031, 10032, 10033, 10034, 10035, 10036, 10037, 10038, 10039, 10040, 10044, 10065, 10069, 10075, 10103, 10110, 10111, 10112, 10115, 10119, 10128, 10152, 10153, 10154, 10162, 10165, 10167, 10168, 10169, 10170, 10171, 10172, 10173, 10174, 10177, 10199, 10271, 10278, 10279, 10280, 10282, 10301, 10302, 10303, 10304, 10305, 10306, 10307, 10308, 10309, 10310, 10311, 10312, 10314, 10451, 10452, 10453, 10454, 10455, 10456, 10457, 10458, 10459, 10460, 10461, 10462, 10463, 10464, 10465, 10466, 10467, 10468, 10469, 10470, 10471, 10472, 10473, 10474, 10475, 11004, 11005, 11101, 11102, 11103, 11104, 11105, 11106, 11109, 11201, 11203, 11204, 11205, 11206, 11207, 11208, 11209, 11210, 11211, 11212, 11213, 11214, 11215, 11216, 11217, 11218, 11219, 11220, 11221, 11222, 11223, 11224, 11225, 11226, 11228, 11229, 11230, 11231, 11232, 11233, 11234, 11235, 11236, 11237, 11238, 11239, 11249, 11354, 11355, 11356, 11357, 11358, 11359, 11360, 11361, 11362, 11363, 11364, 11365, 11366, 11367, 11368, 11369, 11370, 11371, 11372, 11373, 11374, 11375, 11377, 11378, 11379, 11385, 11411, 11412, 11413, 11414, 11415, 11416, 11417, 11418, 11419, 11420, 11421, 11422, 11423, 11424, 11426, 11427, 11428, 11429, 11430, 11432, 11433, 11434, 11435, 11436, 11439, 11451, 11691, 11692, 11693, 11694, 11697.
Reserved
Space reserved for a future, clearly labeled filter retailer link. No affiliate links are live on this site.
Sources
- 2025 Drinking Water Supply and Quality Report (NYC Department of Environmental Protection (DEP)) (nyc.gov, checked Nov 19, 2026)
- Report page (nyc.gov, checked Nov 19, 2026)
- EPA Envirofacts WATER_SYSTEM NY7003493 (data.epa.gov, checked Nov 19, 2026)
- EPA Envirofacts VIOLATION NY7003493 (data.epa.gov, checked Nov 19, 2026)
- EPA Envirofacts LCR_SAMPLE_RESULT NY7003493 (data.epa.gov, checked Nov 19, 2026)
- NSF certified drinking water treatment units listing search (info.nsf.org, checked Nov 19, 2026)
- U.S. Census 2020 ZCTA to place relationship file (www2.census.gov, checked Nov 19, 2026)